Skip to main content

hdfire

water sprinkle

Fire Sprinklers & Accessories

Fire Sprinklers

HD Fire Protect offers a comprehensive range of high-performance fire sprinklers engineered for rapid and effective fire control. Designed to activate automatically at predetermined heat levels, our systems ensure quick water discharge for targeted fire suppression, helping safeguard lives, assets, and infrastructure. Our thermosensitive glass-bulb sprinklers are available in a variety of models, finishes, and temperature ratings to meet diverse hazard classifications and architectural requirements. Manufactured from durable brass, they are offered in chrome, natural brass, and custom colour finishes. For specialized applications, HD sprinklers can also function as open sprinklers (with the glass bulb removed).

UL Listed & FM Approved Fire Sprinklers and Accessories

HD automatic sprinklers are UL Listed and/or FM Approved, ensuring reliable performance and compliance with global safety standards. Designed for seamless integration within wet pipe and other water-based fire protection systems, our solutions deliver consistent and dependable operation.

To support complete system functionality, HD Fire Protect also provides a wide range of accessories, including HD-Flex flexible sprinkler drops, test and drain valves, and check valves. When activated, our sprinklers respond instantly – discharging water at optimal pressure to effectively control or extinguish fires. For detailed technical specifications, approvals, and installation guidelines, please refer to our product catalogue.

Enquire Now

FAQ

What is the liquid inside the glass bulb of a sprinkler?

It contains a non-toxic glycerin solution that expands with heat, causing the bulb to burst and activate the sprinkler.

Why are sprinkler bulbs different colours?

Bulb colours indicate temperature ratings as per NFPA 13 – orange (57 °C), red (68 °C), yellow (79 °C), green (93 °C), and blue (141 °C)

Why do bulb sizes differ?

3 mm bulbs are quick response (QR) and 5 mm bulbs are standard response (SR); smaller bulbs activate faster.

How can I identify an HD Fire sprinkler?

HD sprinklers are marked with “HD” on the frame and have a Sprinkler Identification Number (SIN) on the deflector.

What care the various finished of HD sprinklers?

HD Sprinklers can be supplied with brass, chrome or white finish. 

How do pressure and flow relate for sprinklers?

Flow (Q) = K √P, where K is the sprinkler’s K-factor and P is pressure (bar). For example, a K80 sprinkler at 1 bar gives 80 LPM.

What is the minimum operating pressure?

Typically 0.5 bar (7 psi). Always verify per the model’s technical catalogue. 

Are there spacing limitations?

Spacing should be followed as per NFPA 13 on hazard classification. 

Why isn’t minimum spacing shown on every sheet?

It’s shown only when a listing specifies a different minimum.

Can I use concealed cover plates from another model?

No. It will not be suitable for use with other model of sprinkler. 

Can HD sprinklers be used in both residential and commercial applications?

Yes. Confirm model and hazard class before use.

What does SIN mean?

SIN (Sprinkler Identification Number) is an alphanumeric code identifying the model, K-factor, and response type.

Why can’t I order by SIN only?

SIN doesn’t include finish, temperature rating, or mounting style. Provide full details when ordering.

Why do some SINs change?

As designs are improved, obsolete models receive new SINs. Always refer to the current HD technical catalogue.

Does HD offer non-ferrous sprinklers for MRI or sensitive areas?

Yes. Non-ferrous and low-magnetic sprinklers are available for such environments.

How should dry sprinklers be installed?

Install only in the side outlet of a tee (not an elbow or coupling). Seal properly when installed in refrigerated areas.

What are proper storage and handling precautions?

Store in a dry, temperature-controlled area. Do not drop or handle by the bulb; keep sprinklers in cartons until use.

How do I choose the correct temperature rating?
As per NFPA 13, select a temperature rating higher than maximum expected ambient temperature & the proximity of sprinkler to heat sources or per local code / authority having jurisdiction. For instance: 
  • Ordinary temperature sprinklers (57-77 °C) are used in normal environments such as offices, hotels, or warehouses with controlled temperature.
  • Intermediate temperature sprinklers (79-107 °C) are used near localized heat sources like lighting fixtures, skylights, or warm air ducts.
  • High temperature and above are for industrial or process areas with sustained elevated ambient temperatures (boiler rooms, foundries, etc.).
Can quick-response and standard-response sprinklers be used together?

Yes, if in the same compartment and compliant with NFPA 13. Verify with the authority having jurisdiction and refer to local codes. 

Can concealed sprinklers be installed without a ceiling?

No. Concealed sprinklers are tested and approved for installation only under a ceiling.

What finishes are available for cover plates?

White, chrome, brass, and custom RAL colours are standard; decorative finishes can be considered on request.

Are HD sprinklers UL Listed and FM Approved?

Yes. HD sprinklers carry UL Listing / FM Approval or both, depending on the model. Always refer to HD sprinkler catalogue for details. 

×

Access Information


Please include your country code (e.g. +1 202-555-0123) followed by your mobile number.

Disclaimer

THESE MATERIALS ARE NOT DIRECTED AT OR INTENDED TO BE ACCESSED BY PERSONS LOCATED OUTSIDE INDIA. IMPORTANT: You must read and agree with the terms and conditions of the following disclaimer before continuing. The following disclaimer applies to the draft red herring prospectus of HD Fire Protect Limited (the “Company”) dated September 24, 2025 (the “Draft Red Herring Prospectus”) filed with the Securities and Exchange Board of India (“SEBI“), BSE Limited and National Stock Exchange of India Limited (together, the “Stock Exchanges”), as well as the audio visual film of the Company (the “IPO AV”), in relation to the proposed initial public offering of the equity shares of face value of ₹5 each of the Company (“Equity Shares”) in India (“Offer”). You are advised to read this disclaimer carefully before reading, accessing or making any other use of the Draft Red Herring Prospectus and the IPO AV. In accessing the Draft Red Herring Prospectus and/or the IPO AV, you agree to be bound by the following terms and conditions, including any modifications to them from time to time. THE DRAFT RED HERRING PROSPECTUS IS BEING MADE AVAILABLE ON THIS WEBSITE IN ELECTRONIC FORM SOLELY TO COMPLY WITH THE SECURITIES AND EXCHANGE BOARD OF INDIA (ISSUE OF CAPITAL AND DISCLOSURE REQUIREMENTS) REGULATIONS, 2018, AS AMENDED (“SEBI ICDR REGULATIONS”). THE IPO AV IS BEING MADE AVAILABLE ON THIS WEBSITE IN ACCORDANCE WITH CIRCULAR ON “AUDIOVISUAL (AV) PRESENTATION OF DISCLOSURES MADE IN PUBLIC ISSUE OFFER DOCUMENTS” DATED MAY 24, 2024, ISSUED BY SEBI Each of the Draft Red Herring Prospectus and the IPO AV is directed at, and is intended for distribution to, and use by, residents of India only. No part of the contents of the Draft Red Herring Prospectus and the IPO AV may be copied or duplicated in any form by any means or redistributed. Failure to comply with this disclaimer may result in a violation of the applicable laws. If you access the Draft Red Herring Prospectus and/or the IPO AV, you agree not to forward, deliver or distribute them, in whole or in part, to any person outside India. The Draft Red Herring Prospectus and the IPO AV are for information purposes only and do not constitute, and should not be construed as, directly or indirectly, an offer or invitation to sell or the solicitation of an offer or invitation to purchase any Equity Shares in any jurisdiction. Any such offer or solicitation, if made, would only be made pursuant to the Red Herring Prospectus (“RHP”), which may be filed with the relevant Registrar of Companies in the future (if you are in India) or the RHP and the preliminary international wrap (which contains, among other things, the selling restrictions for the Offer outside India) if the investor is outside India. No person outside India is eligible to bid for Equity Shares in the Offer unless that person has received the preliminary offering memorandum for the Offer, which comprises the Red Herring Prospectus and the preliminary international wrap.   Potential investors should note that investment in the Equity Shares involves a high degree of risk and for details relating to such risks, please refer to the RHP (when available), including the section titled “Risk Factors”, and for potential investors outside India and the preliminary international wrap (when available).   The Equity Shares offered in the Offer have not been and will not be registered, listed or otherwise qualified in any jurisdiction except India and may not be offered or sold to persons outside of India except in compliance with the applicable laws of each such jurisdiction. In particular, the Equity Shares offered in the Offer have not been and will not be registered, listed or otherwise qualified in any jurisdiction except India and may not be offered or sold to persons outside of India except in compliance with the applicable laws of each such jurisdiction. In particular, the Equity Shares offered in the Offer have not been and will not be registered under the U.S. Securities Act of 1933, as amended, or the securities laws of any state of the United States and may not be offered or sold in the United States, except pursuant to an exemption from, or in a transaction not subject to, the registration requirements of the U.S. Securities Act and applicable state securities laws. The Equity Shares offered in the Offer are being offered and sold only outside the United States in “offshore transactions” as defined in and in reliance on Regulation S under the U.S. Securities Act. Ambit Private Limited, Anand Rathi Advisors Limited and IIFL Capital Services Limited (formerly IIFL Securities Limited) (together, the “Book Running Lead Managers”) are the book running lead managers for the Offer and they and their respective affiliates, directors, officers, agents, representatives, advisers and employees do not accept any liability whatsoever, direct or indirect, that may arise from the use of the information contained on this website. The information in the Draft Red Herring Prospectus and the IPO AV is as of the date thereof and none of the Company, the Promoter Selling Shareholders, the Book Running Lead Managers or their respective affiliates, directors, officers, agents, representatives, advisers or employees are under any obligation to update or revise the Draft Red Herring Prospectus and the IPO AV to reflect circumstances arising after the date thereof. You are reminded that documents transmitted in electronic form may be altered or changed during the process of transmission and consequently, neither the Company, the Book Running Lead Managers nor any of their respective affiliates, directors, officers, agents, representatives, advisers or employees accepts any liability or responsibility whatsoever in respect of alterations or changes which have taken place during the course of transmission of the Draft Red Herring Prospectus and the IPO AV in electronic format. You are accessing this website at your own risk and it is your responsibility to take precautions to ensure that it is free from viruses. Capitalised terms used herein but not defined herein have the meaning given to those terms in the Draft Red Herring Prospectus. Due to legal restrictions, access to this part of this website is only available to residents of India from within India.  If you are not in India, please exit this webpage. Confirmation of your acceptance of the terms and conditions By clicking on the “I Confirm” button below you represent to the Company that: 1. You have read the disclaimer set out above and you agree to be bound by its terms; and 2. You are a resident of India and are located in India. If you cannot make these confirmations, you must press the button marked “I Do Not Confirm”.